工作任务 #1483
线扫相机调试
描述
2024.1.29:
今天去大族进行另一个项目的样品进行采图测试
通过现有的光源进行打光采图,目前采出来的效果不理想,治具和产品的阈值较为接近,对比度不是很强。
同时今天共切了4片产品,一片是手动贴的膜(没内缩),三片是原产品为内缩,测量出来的数据都在范围内。
手动贴的膜:
长边上:0.041,0.052,0.036
长边下:0.033,0.035,0.072
短边左:0.033,0.022,0.038
短边右:0.058,0.022,0.054
原产品(内缩):
光斑缩0.3mm
料1
长上边:0.23,0.24,0.26
长下边:0.24,0.24,0.28
短左边:0.29,0.28,0.24
短右边:0.27,0.31,0.33,0.26
上面的数据包含圆弧数据
圆弧:0.27,0.33,0.26,0.29,0.24
光斑缩0.32mm
料2
长上边:0.27,0.29,0.3,0.3
长下边:0.28,0.28,0.31
短左边:0.29,0.32,0.32
短右边:0.29,0.32,0.32,0.3
上面的数据包含圆弧数据
圆弧:0.32,0.29,0.29,0.32,0.3
料3
长上边:0.27,0.29,0.3
长下边:0.27,0.26,0.25
短左边:0.31,0.32,0.31,0.29
短右边:0.28,0.32,0.26,0.25
上面的数据包含圆弧数据
圆弧:0.28,0.26,0.25,0.29,0.31,0.31